At frequencies below a few gigahertz, the impacts of soldering process variations and other manufacturing and assembly factors are typically benign with good design practices.
At frequencies below a few gigahertz, the impacts of soldering process variations and other manufacturing and assembly factors are typically benign with good design practices. At tens of gigahertz, the effects of manufacturing and assembly variations become significant enough that minimizing tolerances in the signal path is critical for many applications. This is why compression-mount test connectors are becoming an increasingly popular solution for high-band millimeter-wave interconnections in testing, prototyping, and diagnostic applications. Another factor to consider is that compression-mount connectors are also compact, which is advantageous as many high-band millimeter-wave applications now feature much higher interconnection density on circuit boards, with less available board space.
However, these connectors are not without challenges. Their compact form factor and required small dimensions increase the risk of misalignment, as the tolerances for these connectors and landing pads are extremely tight. It is entirely possible for a coaxial compression-mount connector to be misaligned without detection until testing begins and unexpected test results are observed. Fortunately, a solution to this dilemma now exists, which provides a clear visual indication of proper alignment and accelerates the assembly and alignment of compression-mount connectors.
Why Compression-Mount Connectors?
There is a growing demand for precision high-frequency test connectors operating at and above 90 GHz. Higher data rates used in backhaul and network infrastructure necessitate the use of RF test equipment for development, validation, and even troubleshooting. Components of millimeter-wave communication and sensing systems, even those operating in the lower V-band, often require testing at many times their maximum operating frequency to characterize nonlinear and harmonic performance.
Whether for planar or coaxial transmission lines, the maximum operating frequency is determined by the dimensions of the conductors and the spacing between them. To implement transmission lines for higher frequencies, the geometries of planar conductors in coaxial connectors and cables, as well as coaxial conductors, must be smaller than those for lower-frequency wavelengths. For certain applications, this is advantageous as it enables higher interconnection density. One example is the large number of antenna feeds in advanced/active antenna systems operating in the high-band millimeter-wave range.
As the physical size of interconnections shrinks, the tolerances associated with interconnection placement and fixation must also become tighter, meaning many alignment strategies suitable for larger interconnections are no longer feasible for miniature high-frequency interconnections.
Key Parameters of PCB Surface Trace Interconnection Solutions:
- Bandwidth (Hz)
- Insertion Loss (dB)
- Return Loss (dB)
- VSWR
- Impedance, typically 50 or 100 Ω
- Power handling capability (dB), usually specified for continuous wave and/or peak power
- Repeatability
- Ease of use and setup
- Cost
PCB Surface Trace Interconnection Solutions
A variety of high-frequency interconnection methods are used to connect test and diagnostic equipment to surface traces or landing pads on PCBs, each with advantages and disadvantages. Coaxial interconnections and broadband planar transmission lines are common in these wideband applications. The interconnection challenge is therefore to ensure a reliable, repeatable, high-precision connection between the landing pads of the planar transmission lines and the test leads of high-frequency test equipment.
PCB Surface Trace Interconnection Solutions:
- Coaxial cables soldered directly to surface-mounted planar transmission lines
- Coaxial connectors that can be surface-mounted, through-hole mounted, or edge-mounted
- Pre-fabricated or custom disposable solder-on test leads
- Coaxial probe stations
- Compression-mount connectors, available in surface-mount or edge-mount configurations
The traditional method is to solder the center conductor and outer conductor (shield) of a coaxial cable directly to the landing pads on the circuit board. This is often used to bridge two surface transmission lines, or when using a truncated section of a coaxial cable assembly to connect a surface transmission line to external equipment. While this method is viable, the relatively large tolerances achievable with hand-soldered and hand-prepared coaxial cable truncations mean this approach may offer the lowest precision and repeatability. Depending on the techniques used, this method is likely unsuitable for millimeter-wave applications unless performed by skilled technicians with specialized equipment.
A more convenient and widely adopted method is to use surface, through-hole, or edge-mounted coaxial connectors soldered to the landing pads. When properly bonded, this method provides a robust, reliable, and compact connection. It does require effort to ensure alignment, but some connector types can be automatically assembled via pick-and-place technology. The main limitation of this method is the tolerance of the solder joints between the center pin and ground of the coaxial connector and the landing pads. At 100 GHz, the free-space wavelength is approximately 3 mm. A common rule of thumb is that geometric dimensions of one-tenth or even one-twentieth of a wavelength are critical. This means that solder joint dimensions of less than 300 microns or even 150 microns are mandatory for high-precision and repeatable interconnection applications. This is difficult to achieve manually without the expertise of skilled technicians and specialized tools, but it is within the capability of automated assembly.
One solution to the repeatability issue is the use of pre-fabricated or custom solder-on test leads. However, the frequency limitations of this solution make it more suitable for probing time-domain signals at a few gigahertz with oscilloscopes. These connection types have a maximum frequency capability of only 20 GHz. They are also costly to use and often limited to single-use or a few uses at most. Ultimately, these connectors are not suitable for high-band millimeter-wave applications.
An alternative approach is to avoid soldering test leads to landing pads and instead press precision contacts of the transmission line onto the landing pads. Probe stations can test these board-level test points and transmission lines with minimal impact on the test board. Some precision probes use ground-signal-ground type probe tips with waveguide interconnections, achieving bandwidths up to 500 GHz. Alternatively, precision probes using coaxial interconnections can reach 145 GHz. Some probes feature multiple signal lines on one probe head, which facilitates testing of multiple high-speed differential lines. However, the use of precision probes requires a probe station, which is typically a major capital expenditure, and also requires experienced technicians for operation.
About Maxipcb
Maxipcb empowers innovators to turn cutting-edge technologies into reality.
We offer one-stop solutions for design, simulation, testing, PCB manufacturing, component procurement and SMT assembly, enabling efficient development, rapid deployment and risk control across the full product lifecycle.Serving the world in communications, industrial automation, aerospace, automotive, semiconductor and beyond, we build a safer, more connected future together.